l1.gif (644 bytes) lbck.gif (178 bytes) upprgt1.gif (1168 bytes)

Company Background | Vision / Quality Policy | Plant Profile | Manpower Profile
Manufacturing Capability | Product Lead Time |
Value Added Services | Production Capacity
CEC Growth | Major Customers | Reliability Program | Equipment | Officers


  • Reliability Program
Test Analysis Process
Location
Freq. Simple
Size
Test
Equipment
Remarks
A. PRODUCT          
_1. Plating & Ink __Thickness __Measurement          
1.1 Microsection HAL
CuTL
monthly
monthly
1 sample/DC
1 sample/DC
Microscope in-house
1.2 Coating __Measurement CuTL/SES
HAL
NiAu Plating
2x/month
2x/month
2x/month
1 sample/DC
1 sample/DC
1 sample/DC
CMI XRX MRX PTX
CMI XRX PTX
CMI XRX
in-house
in-house
in-house
2. Solderability          
2.1 CEMCO Rotary __solderability __Test FVI/FG 2x/month 1 sample/DC CEMCO Rotary solderability Test in-house
2.2 HAL FVI/FG 2x/month 1 sample/DC TIM HAL Machine in-house
3. Plating __Adhesion Test PTH
CuTL
Tab Plating
2x/month
2x/month
2x/month
1 sample/DC
1 sample/DC
1 sample/DC
3M Cellophane Tape 600
in-house
in-house
in-house
4. Marking Paints & __Inks Adhesion __Test LPSM
Legend
FVI
2x/month
2x/month
2x/month
1 panel/DC
1 panel/DC
1 panel/DC
3M Cellophane Tape 600
in-house
in-house
in-house
5. Ionic __Contamination __Test OQA 2x/month 1 sample/DC SMD 600 Omega Meter in-house
6. soldermask Ink __Hardness Test LPSM 2x/month 1 panel/DC Staedler Pencil 1H-6H in-house
7. Practice Test __Count DF Imaging
LPSM
2x/month
2x/month
N/A
N/A
Laser Particle Counter in-house
in-house
B. PROCESS.          
1. Solder Bath __Analysis HAL        
_Cu contamination _level   monthly 500 grams Spark Emission outside
2. Additive Level CuTL        
__2.1 Copper   2x/month 200 ml CVS outside
__2.2 Copper   2x/month 250 ml Hull Cell in-house
__2.3 Tin Lead   2x/month 250 ml-1 liter   outside
3. Cu __Contamination/
   Concentration
         
3.1 Black Oxide Black Oxide     Titration in-house
__Microetch ______Solution   < 50g/liter 1 ml   in-house
3.2 Desmear Line Desmear     AA Machine / Titration in-house
__Neutralizer ______Solution   < 10g/liter 5 ml    
3.3 PTH Line PTH        
_3.3.1 Microetch   < 50g/liter 1 ml AA Machine / Titration in-house
3.4 OMIG _Microetch CuTL 130,00 SF N/A N/A in-house
3.5 Etching SES <22oz/gal 1 ml AA Machine / Titration in-house
_Ammonical ____Etchant          
3.6 Ni/Au          
_Ni Bath TAB if necessary 10 ml AA in-house
_Au Bath TAB if necessary 10 ml AA in-house
4. Palladium _Concentraion PTH daily 10 ml Pico Pd Analyzer in-house
5. Copper _Concentration CuTL daily 5 ml Titration in-house
6. Sulfuric Acid _Concentration CuTL daily 5 ml Titration in-house
7. Chloride Molarity SES every other day 50 ml Titration in-house
8. Acid to Copper ___Ratio CuTL   N/A Computation in-house
9. Carbon ___Treatment CuTL every 6 mos. All Copper Solution   in-house
10. Ni _Concentration TAB every 2-4 hrs. 2 ml Titration in-house
_Au Concentration TAB if necessary 10 ml AA in-house

 

 

http://www.yahoo.com
http://www.infoseek.com
http://www.lycos.com
http://www.tucows.com
http://www.yehey.com
http://www.antivirus.com
http://www.hotmail.com
http://www.cnn.com


JG Summit Holdings, Inc.

_A Company of
_JG Summit Holdings

Copyright © 1999
Cambridge Electronics Corporation
Tel. Nos.: 63 (046) 402 - 0361 / 402 - 0363 to 66
Fax No.: 63 (046) 402 - 0362
e-mail: cambridge@jgsummit.com
webmaster@cambridge